Sole Proprietorship
NADRA CITIZENSHIP (CNIC/NICOP)
FBR (NTN)
FBR (GSTN)
| Eligibility Criteria | Document |
|---|---|
| • The contractor shall dismantle the motor and diagnose all faults. • Rewinding shall be done using 100% Electrolytic Copper Wire (no aluminum substitute). • Insulation Class: Minimum Class 'B' (130°C) or 'F' (155°C) varnished insulation. • Warranty: Minimum 6 months on rewinding and workmanship from the date of commissioning. | |
| • Bearings: o Type: Double-shielded deep groove ball bearings. o Quality: Standard quality (equivalent to SKF, FAG, NSK, or ZKL). o Note: Both Drive End (DE) and Non-Drive End (NDE) bearings to be replaced. • Capacitor: o Type: Motor-run / Starting Capacitor (as per motor design). o Rating: Same µF (microfarad) and Voltage (VAC) rating as the original (to be verified during dismantling, e.g., 25µF to 40µF / 450V typical for 1 HP). o Quality: Dry or Oil-filled type with thermal prot | |